2 - 2 MP6000 BAR CODE PROGRAMMING GUIDE
RS-232 Parameter Defaults
Table 2-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar
code(s) provided.
NOTE See Appendix A, STANDARD DEFAULT PARAMETERS for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 2-1
RS-232 Host Default Table
Parameter Default
Page
Number
RS-232 Host Parameters
RS-232 Host Types Standard
2-7
Baud Rate 9600
2-18
Parity Type None
2-23
Stop Bits 1
2-26
Data Bits 8-bit
2-28
Check Receive Errors Enable
2-30
Hardware Handshaking None
2-32
Software Handshaking None
2-38
Host Serial Response Timeout 2 Sec
2-44
RTS Line State Low RTS
2-49
Beep on <BEL> Disable
2-51
Intercharacter Delay 0 msec
2-53
Wincor-Nixdorf Beep/LED Options Normal Operation
2-58
Ignore Unknown Characters Send Bar Code
2-61
NCR Use Prefix Enabled
2-63
NCR Prefix 1002 (STX)
2-65
NCR Suffix 1003 (ETX)
2-66
NCR Use Block Check Character Enabled
2-67
NCR Interface Follow System
2-69