Zebra R-140 Guia do Utilizador Página 30

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 29
Media and Ribbon Calibration
NOTE: All steps must be performed in the following procedure, even if
only one sensor needs to be adjusted.
6. Press the SETUP/EXIT key.
7. Press the NEXT/SAVE key until “MEDIA AND RIBBON
CALIBRATE” displays.
8. To start the calibration procedure, press the RIGHT BLACK OVAL
key. “LOAD BACKING CANCEL CONTINUE” displays.
9. Open the printhead. Remove approximately 8” (203 mm) of labels
from the media roll, enough so that only the backing material is
threaded between the media sensors when the media is loaded
(refer to Figure 10).
Zebra R-140 User’s Guide 21
Figure 10
Vista de página 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 125 126

Comentários a estes Manuais

Sem comentários