Zebra II Especificações Página 140

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 412
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 139
ZPL Commands
^CV
120
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
Comments If more than one error exists, the first error detected is the one displayed.
The
^CV command tests the integrity of the data encoded into the bar code. It is not used for
(or to be confused with) testing the scan-integrity of an image or bar code.
Example • The examples below show the error labels ^CVY generates when incorrect field
data is entered. Compare the letter following INVALID – to the listing on the previous page.
^XA
^CVY
^FO50,50
^BEN,100,Y,N
^FD97823456 890^FS
^XZ
ZPL II CODE
GENERATED LABEL
^XA
^CVY
^FO50,50
^BEN,100,Y,N
^FD9782345678907^FS
^XZ
^XA
^CVY
^FO50,50
^BEN,100,Y,N
^FD97823456789081^FS
^XZ
^XA
^CVY
^FO50,50
^BEN,100,Y,N
^FD97823456789^FS
^XZ
^XA
^CVY
^FO50,50
^BQN2,3
^FDHM,BQRCODE-22^FS
^XZ
Vista de página 139
1 2 ... 135 136 137 138 139 140 141 142 143 144 145 ... 411 412

Comentários a estes Manuais

Sem comentários