Chapter 3 KERBEROS PARAMS
Kerb. Pwd(16–30)
Characters 31 to 40 of the Kerberos password (maximum number of
characters is 40).
Kerb. Pwd(31–40)
Characters 31 to 40 of the Kerberos password (maximum number of
characters is 40).
Reset Kerb. Pwd
Resets Kerberos password to an empty string.
KDC Port Number
KDC (Key Distribution Center) port number is the 2-byte UDP/TCP port used
for Kerberos Communication.
The range is 0-65535, and the factory default is 88.
Clock Skew Units
The options are Seconds and Minutes, and the factory default is Seconds.
Clock Skew (SEC)
Sets the maximum allowable amount of time in seconds (SEC) or minutes
(MIN), as specified by the Clock Skew Units, that Kerberos authentication will
tolerate before assuming that a Kerberos message is invalid.
Seconds: The range is 60-900, and the default is 300.
Minutes: The range is 1-15, and the default is 5.
NOTE: Whatever submenu is selected in Clock Skew Units will display on the
Clock Skew (SEC) menu. For example, if you select Minutes, the
Clock Skew (SEC) menu name will change to Clock Skew (MIN).
Tckt Life Units
Ticket lifetime unit in Seconds, Minutes, Hours, or Days.
The factory default is Seconds.