Data Ports
Applicator Interface Connector
130
57516L-002 Rev. A 170PAX4 User Guide 1/10/06
11 END PRINT Output See Applicator Signals on page 126 for more information
about the start and end print signals. See Set Applicator
Port Mode on page 76 for more information about the
modes.
MODE 0—The applicator port is OFF.
MODE 1—Asserted LOW only while the print engine
is moving the label forward; otherwise deasserted
HIGH.
MODE 2—Asserted HIGH only while the print engine
is moving the label forward; otherwise deasserted
LOW.
MODE 3—(Default) Asserted LOW for 20
milliseconds when a label is completed and positioned.
Not asserted during continuous printing.
MODE 4—Asserted HIGH for 20 milliseconds when a
label is completed and positioned. Not asserted during
continuous printing.
12 MEDIA OUT Output Asserted LOW while there is no media in the
print engine.
13 RIBBON OUT Output Asserted LOW while there is no ribbon in the
print engine.
14 DATA READY Output See Applicator Signals on page 126 for more information
about this signal.
Asserted LOW when sufficient data has been received
to begin printing the next label.
Deasserted HIGH whenever printing stops after the
current label, due to either a pause condition or the
absence of a label format.
15 SPARE Output To be determined.
Table 19 • Applicator Interface Connector Pin Configuration (Continued)
Pin
No.
Signal Name Signal Type Description