Zebra TTPM2 Especificações Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 140
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
21
Installation
Electrostatic Discharges and Earth Currents
09/14/2009 TTP 2000 Technical Manual P1002902-002
Electrostatic Discharges and Earth Currents
Preventing ESD and earth currents from affecting the printer operation requires proper
connection of the printer chassis to protective earth through a mounting platform or through a
separate earth conductor.
Ambient Light
There is an optical sensor 20 mm behind the paper exit at the front of the printer.
To ensure proper printer operation, design the printer enclosure so that it prevents direct
sunlight or light from indoor lamps from reaching the sensor through the paper exit.
Vista de página 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 139 140

Comentários a estes Manuais

Sem comentários