ZPL Commands for Wireless Operation
^WI
4/29/08 Wireless User Guide 14143L-005 Rev. A
h = ARP broadcast
interval
Time, in minutes, that the broadcast is sent to update the
device’s ARP cache.
Accepted Values: 0 through 30
Default Value: 0 (no ARP sent)
i = base raw port number
The port number that the printer should use for its RAW data.
Accepted Values: 1 through 65535
Default Value: 9100