Section 14
Configuration/
Control
Commands
pg. 14-32
continued
device.download_connection_timeout
type: getvar; setvar
This parameter instructs the printer to abort a firmware download if the printer fails to receive any
download data in the set amount of seconds. If the set amount of seconds is exceeded, the download will
be aborted and the printer automatically restarts. This command prevents the printer from being locked in
the downloading state if the communications host is interrupted.
getvar result The connection time out value (in seconds).
Example
Description Retrieves the connection time out value (in seconds).
Syntax ! U1 getvar ”device.download_connection_timeout
Result “ 0
setvar choices
Values: “0” through “65535”
Default “0“ (“0” disables this feature)
Example
Description
Instructs the printer to abort a firmware download if the printer
fails to receive any download data in the set amount of seconds.
Syntax ! U1 setvar “device.download_connection_timeout” “0