• 2-67 • RMAN-RWS-001 rev. B • RW Series Repair Procedures
Replacing the Platen Assembly
Remove the Old Platen Assembly
1. Remove and retain the two screws holding the Holder, Platen to the Media
Cover.
2. Carefully rotate the Holder, Platen towards the interior of the printer until it is
free from the media cover.
Caution•Avoidputtingstrainonthesensorcablewhichisadheredtotheinside
of the Holder, Platen. Do not exert excessive force on the Holder, Platen when it is
removed from the Media Cover.
3. Remove the Platen Assembly from the Holder, Platen.
Install the New Platen Assembly
1. Install the new Platen Assembly into the Holder, Platen, noting the location of
the Gear at “1”.
2. Rotate the Holder, Platen back into the Media Cover until it snaps into place as
shown at “2”. Ensure that the new Platen Assembly spins freely.
3. Secure the Holder, Platen to the Media Cover with the (2) retained Screws.
Replacement Kit RK17949-002- RW 220 Platen/Gear
Installation Instruction
This kit includes the parts and documentation necessary to install the RK17974-002
Platen/Gear Kit in the RW 220 model printer. Read these instructions thoroughly
before attempting to install this kit.
Caution•TheoperatormustwearaproperlygroundedESDstraptoperformthe
following repair procedure.
Reference Materials
UMAN-RWS RW Series Users’ Guide
Tools Required
#0 or #1 Phillips Head Screw Driver
Cautions
Caution•Thisinstallationmustbeperformedonlybyaqualiedservicetechnician.
Unless otherwise specied:
• Always turn the printer off
• Remove the battery before installing any Replacement Kits.
• Remove media before installing this Replacement Kit.
continued on next page